C9010-262 予想試験 - IBM Power Systems With POWER8 Enterprise Technical Sales Skills V2

 

NO.1 A customer would like to have a mirrored pair of SAS disks server with dual VIOS.
What is needed to accomplish this?
A. Four 300GB drives in PCIe Gen3 drawer Two SAS adapters
B. Four 300GB drives. EXP24S in mode 1 Two SAS adapters
C. Four 300GB drives. EXP24S in mode 2 Integrated SAS adapters
D. Four 300GB drives. EXP24S in mode 2 Two SAS adapters
Answer: B

C9010-262 出題   

NO.2 Which of the following statements about Power Enterprise Pools is true?
A. A transfer entitlement agreement must be signed before each move of mobile core activations and
workloads between Authorized Machines in the Power Enterprise Pools.
B. A temporary CoD AIX and PowerVM license must be purchased before moving core activations
between Authorized Machines in the Power Enterprise Pool.
C. All static cores on all Authorized Machines in the Power Enterprise Pool must be licensed for
Power VM and AIX.
D. Any licenses for IBM AIX, IBM I, and other Power Systems Software that exist on any system in a
pool must also be licensed for at least one core on each of the additional systems in the pool.
Answer: D

NO.3 Customers want to implement a private cloud on a Linux Power server.
Which Linux operating system needs to be loaded to install PowerVC?
A. Ubuntu
B. Debian
C. SUSE
D. RHEL
Answer: D

C9010-262 リンクグローバル   
Explanation:
Explanation
PowerVC installs on RHEL 7.1+ and will need access to the Red Hat Network (RHN) in order to install
the necessary required packages that are available from Red Hat.
Reference
https://www.ibm.com/developerworks/community/wikis/home?lang=en#!/wiki/Wc1c29d23e0fd_43
46_b509_f1c00a2099f0/page/PowerVC%201.3%20Installation%20Tips

NO.4 A customer is purchasing a 1-node E870 and requires the following:
What can be added to the E870 to satisfy their requirement?
A. Two PCIe I/O Drawers, redundant SAS controllers, and an EXP24S in mode 2.
B. A PCIe I/O Drawer, redundant SAS controllers, and an EXP24S in mode 1.
C. Redundant SAS controllers and an EXP24S in mode 4.
D. An EXP24S in mode 2 connected to the integrated SAS controller.
Answer: A

C9010-262 ガイド   
Explanation:
The EXP24S SFF Gen2-bay Drawer (#5887) is an expansion drawer with twenty-four 2.5- inch form
-factor SAS bays.
With AIX, Linux, and VIOS, you can order the EXP24S with four sets of six bays, two sets of 12 bays, or
one set of 24 bays (mode 4, 2, or 1).
It is recommended for SAS cabling ease that the EXP24S drawer be located in the same rack in which
the PCIe adapter is located. Note, however, it is often a good availability practice to split a SAS
adapter pair across two PCIe drawers/nodes for availability and that may make the SAS cabling ease
recommendation difficult or impossible to implement.

あなたはIBMのC9010-262 予想試験の資料を探すのに悩んでいますか。心配しないでください。私たちを見つけるのはあなたのIBMのC9010-262 予想試験に合格する保障からです。数年以来IT認証試験のためのソフトを開発している我々JapanCertチームは国際的に大好評を博しています。我々はIBMのC9010-262 予想試験のような重要な試験を準備しているあなたに一番全面的で有効なヘルプを提供します。

JapanCertのIBMのC9010-262 予想試験を利用すれば、認定試験に合格するのは簡単になります。うちのIBMのC9010-262 予想試験は豊富な経験を持っている専門家が長年の研究を通じて開発されたものです。JapanCertの学習教材は君の初めての試しでIBMのC9010-262 予想試験に合格するのに助けます。

C9010-262 予想試験は専門知識と情報技術を検査する試験で、JapanCertが一日早くIBMのC9010-262 予想試験に合格させるのサイトで試験の前に弊社が提供する訓練練習問題をテストして、短い時間であなたの収穫が大きいです。

C9010-262試験番号:C9010-262 合格体験談
試験科目:「IBM Power Systems with POWER8 Enterprise Technical Sales Skills V2」
最近更新時間:2017-06-20
問題と解答:165

>> C9010-262 合格体験談

 

JapanCertは最新のC_HANATEC_11問題集と高品質の400-201問題と回答を提供します。JapanCertの70-742 VCEテストエンジンと300-209試験ガイドはあなたが一回で試験に合格するのを助けることができます。高品質の1z1-588 PDFトレーニング教材は、あなたがより迅速かつ簡単に試験に合格することを100%保証します。試験に合格して認証資格を取るのはそのような簡単なことです。

記事のリンク:http://www.japancert.com/C9010-262.html